TM 9-2350-222-20-1-5
PUMP MOUNTING BRACKET REPLACEMENT (Sheet 1 of 1)
3/4 in. combination box and open end wrench
TOOLS:
Lockwasher (MS35338-48) (3 required)
SUPPLIES:
PRELIMINARY PROCEDURE:
NOTE
Clamp may be secured by one
of three screws (A).
REMOVAL:
1.
Using wrench, remove three screws and lock-
2.
Using wrench, loosen screw and lockwasher (B).
3.
Pull bracket (C) toward you, slipping it loose
from screw and lockwasher (B).
4.
Using wrench, remove three spacers (D).
1.
Using wrench, install three spacers (D).
2.
Position bracket (C) on screw (B).
NOTE
Place clamp (E) in position, if
removed.
3.
Using wrench, install three screws and new
Install right angle drive, clutch, and pump
End of Task
TA253662