TM 9-2350-222-20-1-5
MOLDBOARD LOCKING HOOKS AND SHAFT REPLACEMENT (Sheet 4 of 6)
NOTE
Count and write down the number
of turns required to remove clevis
(C).
13. Using 3/4 inch wrench on nut (S) and using
adjustable wrench on clevis (C), loosen nut (S)
and remove clevis (C) from handle (T).
14. Using 3/4 inch wrench on nut (S), remove nut
(S) from handle (T).
15. Remove handle from bracket (U).
INSPECTION:
1.
Check for damaged or defective parts.
2.
Replace damaged or defective parts.
Go on to Sheet 5
TA141125