TM 9-2350-222-20-1-4
BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPAIR (Sheet 6 of 12)
C a b l e Assembly Replacement (Sheet 3 of 4)
CLEANING AND INSPECTION:
1.
Inspect all parts for corrosion. If corroded parts cannot be cleaned using crocus cloth (Item 14,
Appendix D) or steel wool (Item 55, Appendix D), replace parts.
Inspect all parts for mechanical damage and wear. If damaged or worn, replace parts.
2.
INSTALLATION:
1.
Position gasket and cable assembly (A) into
place on enclosure assembly (B) with notch of
cable assembly facing 9 o'clock position as you
face it.
2.
Using screwdriver, install four screws (C) with
3.
Place lead 450A onto terminal of circuit
breaker (D).
4.
Using 7/16 inch socket, install screw (E) with
new lockwasher and flat washer.
Go on to Sheet 4
TA139750
10-195