TM 9-2350-222-20-1-4
BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPAIR (Sheet 3 of 12)
C i r c u i t Breaker Replacement (Sheet 3 of 3)
INSTALLATION:
Position circuit breaker (A) into position in enclosure assembly (B).
1.
Using screwdriver, install two screws (C) with flat washers and new lockwashers.
2.
3.
circuit breaker and one flat washer at
position (E) of relay. Position bus bar (F)
over lockwasher at (D) and (E).
Using socket, install screw and two flat
4.
washers through bus bar on circuit breaker
at position (D).
Using socket, install nut and flat washer to
5.
hold bus bar at position (E).
6.
Using socket, install screw. flat washer, and
new lockwasher (G) to secure lead (H).
7.
Place cover (J) and new gasket (K) into
installation position on enclosure assembly (B).
8.
Using screwdriver, install four screws (L) and
new lockwashers (M).
Install enclosure assembly (B) in vehicle (page
9.
End of Task
TA139747
10-192