TM 9-2350-222-20-1-4
BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPAIR (Sheet 5 of 12)
Cable Assembly Replacement (Sheet 2 of 4)
Using 5/16 inch socket, remove nut (E) with
3.
lockwasher. Throw lockwasher away.
Remove lead 451 and flat washer.
4.
5.
Using 7/16 inch socket, remove nut (F) with
lockwasher and flat washer. Throw lockwasher
away.
Remove lead 451B
6.
Using 7/16 inch socket, remove screw (G)
7.
with flat washer and lockwasher. Throw
lockwasher away.
Remove lead 450A.
8.
Using flat-tip screwdriver, remove four screws
9.
Remove cable assembly and gasket (J) from
10.
enclosure assembly (K).
Throw gasket away if damaged.
11.
Go on to Sheet 3
TA139749