TM 9-2350-222-20-1-4
INFRARED POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT
(Sheet 1 of 5)
PROCEDURE INDEX
PAGE
PROCEDURE
Removal
Inspection
Installation
7/16 in. combination box and open end
TOOLS: 1/4 in. combination box and open
wrench
end wrench
7/8 in. combination box and open end
7/16 in. socket with 1/2 in. drive
wrench
1/2 in. socket with 1/2 in. drive
1 in. combination box and open end wrench
5 in. extension with 1/2 in. drive
Flat-tip screwdriver
SUPPLIES: Lockwasher (MS35338-26) (4 required)
Lockwasher (MS45904-72) (4 required)
REFERENCE: TM 9-2350-222-10
PRELIMINARY PROCEDURES: Open turret platform access door (TM 9-2350-222-10)
Traverse turret to expose infrared power supply, located
directly behind left battery (TM 9-2350-222-10)
REMOVAL:
Using 7/8 inch wrench, disconnect cable (A)
1.
from power supply (B).
2.
Using 1 inch wrench, disconnect cable (C) from
power supply (B).
Go on to Sheet 2
10-202