TM 9-2350-222-20-1-4
BILGE PUMP RELAY ENCLOSURE ASSEMBLY REPAIR (Sheet 10 of 12)
Solenoid Relay Replacement (Sheet 3 of 5)
13. Using fingers, remove ground lead (P) from
solenoid relay (Q).
14. Remove solenoid relay (Q) from relay
enclosure assembly (R).
CLEANING AND INSPECTION:
1.
Visually inspect all parts for corrosion. If corroded parts cannot be cleaned with crocus cloth
(Item 14, Appendix D) or steel wool (Item 55, Appendix D), replace parts.
2.
Visually inspect for mechanical damage and wear. If damaged or worn, replace parts.
INSTALLATION:
1.
enclosure assembly (B).
2.
Place ground lead (C) into position as shown.
3.
Using screwdriver, install two screws (D) with
Go on to Sheet 4
TA139754
10-199