TM 9-2350-222-20-1-4
ELECTRICAL WIRING HARNESS AND CABLE CONNECTOR REPAIR
FEMALE PLUG REPAIR (Sheet 2 of 3)
6.
Pulling cut wire out of grommet (D), use
diagonal cutting pliers to shorten wire about 6
inches. Fasten new end of cut wire to cable (C)
with electrical tape (Item 58, Appendix D).
7.
Using hand wire stripper, strip insulation from jumper
wire equal to depth of contact solder weIl (F)
8.
Placing connector face down on flat surface, apply a
a small amount of silicone (Item 32, Appendix D) to
empty holes on back of plug assembly (B) and on front
of grommet (D).
9.
Push new contact (E) into hole in back of plug
assembly (B) far enough so it will remain
standing.
10. Push jumper wire end through grommet
retaining nut (A) and then through hole in
grommet (D).
Goon to Sheet 3
TA139870
10-319