MWO 9-2350-372-23-1
(5) Using electrical tiedown strap MS3367-1-0 (Figure 6, Kit 57K7628), secure two leads of JCAD cable
assembly 12529157 (Figure 6, Kit 57K7628) to main branch of JCAD cable assembly, as shown. Cut
off excess tiedown strap.
(6) Connect JCAD cable assembly 12529157 (Figure 6, Kit 57K7628) connector P2 to chemical agent
detector wiring harness 12330316, and connect JCAD cable assembly connector P1 to dummy
connector 602 GB-188-10 (Figure 6, Kit 57K7628), as shown.
P1
12529157
P2
TO DUMMY
TO HARNESS
CONNECTOR
12330316
602 GB-188-10
MAIN BRANCH
TWO LEADS
MS3367-1-0
JCAD005
h. Follow-on Tasks
(1) Stow rear platform and step (TM 9-2350-372-10).
(2) Close and secure rear doors (TM 9-2350-372-10).
(3) Connect battery ground leads (TM 9-2350-372-10).
12