TM 9-2350-222-20-1-4
GREASE ACTUATED TRACK ADJUSTING LINK REPAIR (Sheet 2 of 4)
DISASSEMBLY:
WARNING
1.
Clean grease actuated adjusting link (A)
Dry cleaning solvent P-D-880 is toxic and
with solvent (Item 54, Appendix D),
flammable. Wear protective goggles and
brush (Item 10, Appendix D), and rag
gloves and use only in a well-ventilated
(Item 65, Appendix D).
area. Avoid contact with skin, eyes, and
clothes and don't breathe vapors. Do not
2.
Using 3/4 inch socket, remove collar
use near open flame or excessive heat.
locking screw (B).
The flash point for Type #1 Dry Cleaning
Solvent is 100F (38C) and for Type #2
is 138F (50C). If you become dizzy
while using cleaning solvent, get fresh air
immediately and get medical aid. If contact
with eyes is made, wash your eyes with
water and get medical aid immediately.
Using 15/16 inch socket, remove pressure
3.
relief valve (C) and packing (D) from
yoke (E). Throw packing (D) away.
Using 7/16 inch socket, remove two
4.
support link assembly (H). Throw lock-
washers (G) away.
Using 7/16 inch socket, remove grease fitting (J). Throw fitting (J) away.
5.
Using 7/16 inch socket, remove safety relief valve (K).
6.
Go on to Sheet 3
14-62.10
Change 3