TM 9-2350-222-20-1-3
POWERPLANT REPLACEMENT (2D ENGINE) (Sheet 9 of 23)
Manually pull one lockring (AK) on each side
29.
of powerplant to unlock powerplant guides
(AL). Swing guides (AL) rearward from
powerplant until they lock.
30.
Make sure powerplant guide locks (AM) engage when guides (AL) are all the way back.
31. Using 1-1/2 inch socket, remove two capscrews (AP), two lockwashers (AQ), and two flat washers
(AR) holding two mounting brackets (AN) to transmission mounts (AS).
Go on to Sheet 10
TA140225
5-33