TM
5-5420 -226-20-1
DETAILED
TROUBLESHOOTING
PROCEDURE
INDICATOR
- LAMP
(Continued)
Symptom-42
POWERPLANT
WARNING
LAMP ON (ENGINE
RUNNING
ALL GAGES
I
This procedure
is to be performed
by
two
persons.
The
lead
person
is
referred
to as the first technician
and
shall direct the activity of the second
person called the second
technician.
heck engine high oil temperature
switch for short to
ground
(engine
cold).
Second Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
OFF.
First
Technician
(Rear
of Crew
Compartment)
l Remove engine lower access cover (page 17-16).
l Disconnect
engine
electrical
harness
connector
(CKT
509L)
from
engine
high oil temperature
switch.
l Set multimeter
to OHMS
XI scale and zero meter or use
STE/ICE
Test
No. 91 (page
4-83).
l Connect red probe of meter to center contact of high oil
temperature
switch
&d
black
probe
to ground.
l Check if meter indicates
continuity.
Does meter
indicate
continuity,
thereby
indicating
a
short?
1
YHF
TO VEHICLE
II
~
GROUND
ENGINE
HIGH OIL
TEMPERATURE
SWITCH
CKT
509L
~-
01
FRONT
OF ENGINE
(VIEWED
THRU
LOWER
ENGINE
ACCESS
DOOR)
Replace
engine
high oil
temperature
switch
(page
10-219).
TA10719O
--
4-501