TM
5-5420-226-20-1
Symptom-42
.r
DETAILED
TROUBLESHOOTING
PROCEDURE
INDICATOR
- LAMP
(Continued)
Check front accessory
harness
(CKT 509L) at basket
disconnect
for short to ground.
1
Second
Technician
(Operators
Station)
l Connect
basket-control
panel
accessories
harness
connector
to master
control
panel.
l Install master control panel (page 10-33).
l Connect
basket-indicator
panel
harness
connector
to
gage instrument
panel.
l Reconnect
basket-indicator
panel harness
connector
to
powerplant
warning
light assembly.
First
Techncian
(Commanders
Station)
l Disconnect
front
accessory
harness
connector
(CKT
509L)
from
basket
disconnect.
l Connect red probe of meter to contact H (CKT 509L) of
front accessory
harness
connector
at basket
disconnect
and
black
probe
to ground.
l Check if meter indicates
continuity.
Does meter
indicate
continuity,
thereby
indicating
a
short to ground?
!
B
%1-iF
TO VEHICLE
GROUND
J
0/!(
GA OGOF
o
Bo
~o
/--
Oc
00
CONTACT
H
,
(CKT 509L)
BASKET
DISCONNECT
(1)
l Inspect basket-indicator
panel
harness
for bent/broken
connector
contacts
or loose
CKT 509L wire at rear of
connectors.
l Repair connectors
if defective
(page
10-298).
l If connectors
are not
defective,
notify
support
maintenance
of a defective
basket-indicator
panel
harness.
l Connect
front
accessory
harness
connector
to basket
disconnect.
I
TA107194
4-505
9