TM
5-5420-226-20-1
Svmt3tom-41
DETAILED
TROUBLESHOOTING
PROCEDURE
INDICATOR
- LAMP
(Continued)
FROM
STEP
o
4
~Check
basket-indicator
panel harness
(CKT 509L) at
basket
disconnect
for electrical
power.
Second
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
OFF.
First
Technician
(Commanders
Station)
l Reinstall front accessory harness connector
at bulkhead
disconnect
(page
10-270).
l Displace
basket-indicator
panel
harness
connector
(CKT
509L)
at basket
discorqect.
l Connect red proble of meter to contact H (CKT 509L)
of basket-indicator
panel
harness
connector
and black
probe
to ground.
Second
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
ON,
First
Technician
(Commanders
Station)
l Check if meter indicates
18 to 30 volts dc.
Does meter indicate
18 to 30 volts dc?
~
=43
.!
.
0
..
.
m
:
u,
%3
.-
-,
\
,1!
---
)
-n
+
o
II
II
TO VEHICLE
GROUND
/
c
FOR CLARITY
QUADRANT
ASSEMBLIES
NOT SHOWN
)
l Inspect
front accessory
harness
for bent/broken
connector
contacts
or loose
CKT 509L wire at rear of
connectors.
l Repair connectors
if defective
(page
10-298).
l If connectors
are not
defective,
notify support
maintenance
of a defective
front accessory
harness.
l Install basket-indicator
panel
harness
connector
at basket
disconnect.
{
TA107187
4-498