TM 9-2350-222-34-1
TRACK ADJUSTING LINK REPAIR (Sheet 11 of 13)
21. Turn needle valve handle (M) counterclockwise until
gage (AA) indicates zero psi, then turn handle (M)
clockwise until closed.
22. Using 7/8 inch wrench, remove test fixture plug (AB)
from manifold block hole (W) and return plug (AB) to its
storage hole (AC) in test fixture frame.
23. Using 7/8 inch and 5/8 inch wrenches,
disconnect hose assembly (R) with adapter (S)
from relief valve hole (T) in adjusting link yoke
(C).
24. Using 7/8 inch and 5/8 inch wrenches, install
hose assembly (R) with adapter (S) in manifold
block hole (W).
Go on to Sheet 12
TA248776
Change 2 9-39