TM 9-2350-222-20-1-5
SMOKE GENERATOR FRONT ENGINE FUEL HOSE REPLACEMENT (Sheet 3 of 4)
6.
Using socket, rermove three assembled washer screws (F) securing clamps (G) to engine.
7.
Using 1 inch wrench to hold adapter (H), use 7/8 inch wrench to disconnect smoke generator fuel
hose (A) from fuel shutoff valve (J).
8.
Remove smoke generator fuel hose (A) from engine.
9.
Remove four clamps from hose (A) and throw hose away.
INSTALLATION:
1.
Install four clamps onto smoke generator fuel hose (A).
2.
Position smoke generator fuel hose (A) under electrical cables and along edge of shroud as
indicated.
3.
Remove cap from inlet port of fuel shutoff valve (B) and connect smoke generator fuel hose (A) to
inlet port of fuel shutoff valve (B). Using wrench, tighten hose (A).
Go on to Sheet 4
TA140872