TM 9-2350-222-20-1-5
BILGE PUMP REPLACEMENT (Sheet 1 of 6)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
Cleaning and Inspection
Installation
TOOLS:
9/16 in. combination box and open end wrench
2 in. open end wrench
7/16 in. combination box and open end wrench
Flat-tip screwdriver
1/2 in. combination box and open end wrench
Slip joint pliers
Drycleaning solvent (Item 54,
SUPPLIES:
Gasket (10873214)
Silicone compound (Item 32,
Lockwasher (MS35338-45)
(7 required)
Lockwasher (MS35338-46) (2 required)
Lockwasher (MS35335-34) (6 required)
REFERENCE: TM 9-2350-222-10
REMOVAL:
1.
Using pliers, disconnect connector (A) from
electrical connector (B) on bilge pump assembly (C).
Using screwdriver, loosen lower hose clamp (D).
2.
Disconnect hose (E) from bilge pump adapter (F).
3.
If upper hose clamp (G) is not in position to
4.
be loosened, remove two screws and
inch wrench. Throw lockwashers awav.
If upper hose clamp (G) can be reached, go
to step 6, then step 8.
5.
Rotate hose (E) to a position where upper
hose clamp (G) can be loosened.
6.
Using screwdriver, loosen upper hose clamp (G).
7.
Using 9/16 inch wrench, install two screws
8.
Disconnect hose (E) from elbow (J).
Go on to Sheet 2
TA2538