TM 9-2350-222-20-1-5
HYDRAULIC SUCTION LINE SHUTOFF VALVE REPLACEMENT (Sheet 4 of 6)
15. Using vise to hold handle (M) and using ham-
mer and cold chisel between name plate (Q)
and handle (M), pry out two screws (R) from
handle (M) and name plate (Q). Throw screws
away.
NOTE
Heads of screws may break off
Use 1/8 inch
during removal.
twist drill to drill out shafts of
screws.
,
In driver's compartment, using hammer and
cold chisel between name plate (S) and
reservoir, pry out four screws (T) and take off
name plate (S). Throw screws away.
CLEANING AND INSPECTION:
Inspect all parts closely for damage or wear.
Clean valve, drain cock, flanges, and adapter
with dry cleaning solvent (Item 54, Appendix
3.
Replace damaged or worn parts.
INSTALLATION:
1.
Place handle (A) in vise using hammer to
install name plate (B) with two screws (C).
Go on to Sheet 5
TA141183