TM 9-2350-222-20-1-4
MASTER CONTROL PANEL REPAIR (Sheet 64 of 65)
Fuel Shutoff/Fuel Pump Wiring Harness Replacement (Sheet 1 of 2)
PROCEDURE INDEX
PAGE
PROCEDURE
Removal
Installation
3/8 in. socket with 1/2 in. drive
SUPPLIES: Silicone compound (Item 32, Appendix D)
Lockwasher (MS35338-43)
PRELIMINARY PROCEDURE:
REMOVAL:
Using socket, remove nut (A), lockwasher (B), and flat washer (C) securing harness junction (D) to
1.
panel. Throw lockwasher away.
Remove harness junction (D) and position aside.
2.
Remove circuit 54 connector from fuel shutoff circuit breaker (E).
3.
Remove circuit 76 connector from fuel pump circuit breaker (F).
4.
Disconnect circuit 76 connector from fuel pump switch (G).
5.
Remove circuit 54 connector fuel shutoff switch (H).
6.
Remove wiring harness (J
7.
Go on to Sheet 2
TA139674
10-118