TM 9-2350-222-20-1-4
MASTER CONTROL PANEL REPAIR (Sheet 31 of 65)
Circuit Breaker Replacement (Sheet 2 of 7)
REMOVAL OF BILGE PUMP AND GAS PARTICULATE, IR POWER, FUEL SHUTOFF, AND
UTILITY OUTLET CIRCUIT BREAKERS:
1.
Using fingers, remove two electrical connectors from rear of circuit breaker (A) by pulling out,
NOTE
If necessary, use wrench to hold nuts (D) while removing
screws (B).
2.
Using cross-tip screwdriver, remove two screws (B), lockwashers (C), and nuts (D) securing circuit
breaker (A) to panel. Throw lockwashers away.
3.
Remove circuit breaker (A).
INSTALLATION OF BILGE PUMP AND GAS PARTICULATE, IR POWER, FUEL SHUTOFF, AND
UTILITY OUTLET CIRCUIT BREAKERS:
1.
Place circuit breaker (A) in position on panel.
NOTE
If necessary, use wrench to hold nuts (D) while installing
screw (B).
2.
Using screwdriver, install two screws (B), new lockwashers (C), and nuts (D).
3.
Apply silicone compound (Item 32, Appendix D) to two male electrical connectors for circuit
breaker (A).
4.
Using fingers, connect two electrical connectors in rear of circuit breaker (A) by pushing in,
Goon to Sheet 3
TA139641
10-85