TM 9-2350-222-20-1-4
MASTER CONTROL PANEL REPAIR (Sheet 35 of 65)
Circuit Breaker Replacement (Sheet 6 of 7)
INSTALLATION OF GAGE CIRCUIT BREAKER:
1.
Place circuit breaker (A) in position on panel.
2.
Using cross-tip screwdriver, install two screws (B) and new lockwashers (C).
3.
Apply silicone compound (Item 32, Appendix D) to two male electrical connectors on circuit
breaker (A).
4.
Using fingers, connect two electrical connectors in rear of circuit breaker (A) by pushing in.
5.
Position connector (F) to panel.
6.
Using cross-tip screwdriver on screw and
wrench on nut, install and secure four screws
Go on to Sheet 7
TA139645
10-89