TM 9-2350-222-20-1-4
MASTER CONTROL PANEL REPAIR (Sheet 36 of 65)
Circuit Breaker Replacement (Sheet 7 of 7)
REMOVAL OF MANIFOLD PREHEAT CIRCUIT BREAKER:
1.
Using fingers, disconnect two electrical connectors from rear of circuit breaker (A) by pulling out.
2.
Using cross-tip screwdriver, remove two screws (B) and lockwashers (C) securing circuit breaker (A)
to panel. Throw lockwashers away.
Remove circuit breaker (A).
3.
INSTALLATION OF MANIFOLD PREHEAT CIRCUIT BREAKER:
1.
Place circuit breaker (A) in position on panel.
2.
Using cross-tip screwdriver, install two screws (B) and new lockwashers (C) securing circuit
breaker (A) to panel.
3.
Apply silicone compound (Item 32, Appendix D) to two male connectors for circuit breaker (A).
4.
Using fingers, connect two electrical connectors in rear of circuit breaker (A).
5.
End of Task
TA139646
10-90