MASTER CONTROL PANEL REPAIR (Sheet 33 of 65)
Circuit Breaker Replacement (Sheet 4 of 7)
INSTALLATION OF FUEL PUMP CIRCUIT
BREAKER:
1.
Place circuit breaker (A) in position on panel.
NOTE
If necessary, u s e pliers to hold
n u t s (D) while installing screws
(B).
2.
Using screwdriver, install two screws (B), new
3.
Apply silicone compound (Item 32, Appendix D)
to two male electrical connectors for circuit
breaker (A).
4.
Using fingers, connect two electrical connectors
(E) and (F) in rear of circuit breaker (A) by
pushing in.
5.
Position harness junction (G) onto stud.
6.
Using socket, install flatwashers (H), new
junction (G) to panel
TA139643