TM 9-2350-222-20-1-5
TURRET INFLATABLE SEAL MANIFOLD, GAGE, AND RELATED PARTS REPLACEMENT (Sheet
6 of 10)
INSTALLATION:
1.
Install manifold (A) in vise.
2.
Using 9/16 inch wrench, install adapter (B) into
manifold (A).
3.
Install new preformed packing (C) onto adapter
(B).
NOTE
Install check valve (D) with arrow
pointing toward manifold (A).
4.
Using 1-1/16 inch wrench, install and tighten
check valve (D) onto adapter (B).
5.
Install preformed packing (E) onto connector
(F).
6.
Using 9/16 inch wrench, install connector (F) with preformed packing (E) into check valve (D).
7.
Using 7/16 inch wrench, install elbow (G) into manifold (A).
Using 7/16 inch wrench, install drain cock (H) into manifold (A).
8.
NOTE
Position pressure gage (J) indicator face to face with drain cock (H).
9.
Install pressure gage (J) into manifold (A) and tighten with 9/16 inch wrench.
Go on to Sheet 7
TA140662