TM 9-2350-222-34-1
FINAL DRIVE REPAIR (Sheet 10 of 30)
of case bearing cap surface (AC) to top of
parallel straight bar a minimum of four times at
four equally spaced points.
Record
measurements.
45. If all measurements are between p4479 inches
and 4.489 inches (113.7666 and 114.0206 mm),
go to step 47.
46. If any measurement is not within tolerance,
reassemble
final
drive
and
tag
"UNSERVICEABLE (CASE BEARING BORE
DEPTH)." Return final drive to supply for depot
rework.
NOTE
Ensure case bearing bore surface
(AE) is clean.
bearing bore (AE) diameter a minimum of four
times at four equally spaced points. Record
measurements.
48. If all measurements are between 5.5112 inches
and 5.5130 inches (139.9845 and 140.0302
mm), go to step 50.
49. If any measurement is not within tolerance,
reassemble
final
drive
and
tag
"UNSERVICEABLE (CASE BEARING BORE
DIAMETER)." Return final drive to supply for
depot rework.
Go on to Sheet 11
Change 5 7-10