TM 9-2350-222-34-1
b. Perform tests as specified in the following table. Output voltage should not exceed 15 kilovolts during tests.
vdc input
load resistors
High voltage output
(minimum kilovolts)
24
160 megohms
15.2
18
1-megohms
15.5
24
8 megohms
13.8
28
80 megohms
14.0
INSTALLATION: Refer to 9-2350-222-20-1-4
End of Task
Change 4 5-98