TM 9-2350-222-202-3-2
36-72. ELEVATION SCREW JACK HANDLE INSTALLATION PROCEDURE
TOOLS: External retaining ring pliers
Flat tip screwdriver
New retaining ring
SUPPLIES:
PERSONNEL: One
REFERENCES: JPG for procedures to:
Connect electrical connectors
Install retaining ring
TM 9-2350-222-10 for procedure to elevate and depress caliber .50 machine gun
EQUIPMENT LOCATION INFORMATION:
CALLOUT
FOLDOUT
EQUIPMENT
11
Driver's Master Control Panel
21
Elevation Screw Jack
EQUIPMENT CONDITION: Driver's master control panel MASTER BATTERY switch set to OFF
Procedure
Step
Place screw jack handle (1) on hand crank (2).
1.
Place flat washer (3) on hand crank (2).
2.
Using pliers, install new retaining ring (4) (JPG).
3.
4.
Connect two electrical connectors (5) (JPG).
5.
Using screwdriver, attach clamp (6) to cupola with screw (7).
NOTE
Follow-on Maintenance Action Required:
Elevate and depress caliber .50 machine gun to check
elevation screw jack handle for proper operation
(TM-lo).
END OF TASK
Para 36-72