TM 9-2350-222-20-2-3-2
32-12. BREECHBLOCK B U F F E R INSTALLATION PROCEDURE (CONT)
Procedure
Step
Put two springs (1) and two plungers (2) in buffer (3).
1.
2.
Put buffer (3) in place on breechblock (4) so plungers push against lower surface of
oburator (5).
Using Allen wrench, attach buffer (3) to breechblock (4) with two screws (6) and two
3.
NOTE
Follow-on Maintenance Action Required:
Close breechblock (TM-10).
END OF TASK
Para 32-12 Cont
32-31/(32-32 blank)