TM 9-2360-222-20-2-3-2
HOLD-OPEN MECHANISM REMOVAL PROCEDURE (CONT)
304.
FRAME 1
PROCEDURE
STEP
Using screwdriver, remove two screws (1) and two lockwashers (1.1) that attach spring clip (2) to hatch
1.
(3). Remove spring clip (2).
Using socket wrench remove two screws (4) and two Iockwashers (4.1) that attach hold-open mechanism
2.
(5) to cupola hatch (3).
Remove hold-open mechanism (5) and any shims (6) between hold-open mechanism (5) and hatch (3).
3.
END OF TASK
Para 30-4 Cont
Change 1 30-13