SMOKE GENERATOR FUEL SHUTOFF VALVE REPLACEMENT (Sheet 4 of 4)
Position assembled fuel shutoff valve (C) and mounting bracket (D) onto engine.
5.
Using 1/2 inch socket, install and tighten two assembled washer screws (G) to secure mounting
6.
bracket (D) to engine.
7.
Connect fuel hose (H) and (J) to fuel shutoff valve (C). Using 7/8 inch wrench, tighten hose
connectors to shutoff valve.
Be sure that fuel shutoff valve is in open position. (Index line atop shaft of fuel shutoff valve will
8.
be in line with two ports of valve.)
WARNING
Never activate smoke generator in a building or closed area or
with personnel near.
9.
Perform smoke screening (TM 9-2350-222-10).
10. Check smoke generator lines for leaks. Correct as necessary.
11. Install engine shroud (page 9-3).
End of Task
TA140882
23-30