TM 9-2350-222-20-1-5
SMOKE GENERATOR SWITCH AND INDICATOR LIGHT MOUNTING BRACKET
REPLACEMENT
(Sheet 1 of 2)
TOOL:
7/16 in. combination box and open end wrench
SUPPLIES: Lockwasher (MS35333-40) (4 required)
PRELIMINARY PROCEDURES: Remove switch and guard (page 23-2)
CAUTION
Support cluster assembly when
removing attaching hardware, as
they
are
common
attaching
hardware for the cluster assembly
and mounting bracket.
1.
Support cluster assembly (A) and, using wrench,
securing cluster assembly (A) and mounting
bracket (C) to mounting plate. Throw
2.
Remove mounting bracket (C).
TA140860
Go on to Sheet 2