TM 9-2350-222-20-1-5
INTERIOR RELEASE MECHANISM REPAIR (Sheet 9 of 11)
17. Insert end of spring (V) through hole in rear of
bracket (E).
18. Using pliers, connect and seat other end of
spring (V) onto connecting pin (W) of pawl (Q).
NOTE
Make sure pawI lever (Q) snaps
downward on forward stroke
cam (K) on
and engages
Also, this
rearward stroke.
check will cause lever (L) to
move at same time as lever (G)
when activated.
Move handle (A) forward and rearward to check
19.
for proper operation.
20. Insert switch guard (X) up through center
hole of retainer (Y) and connect to retainer
(Y).
Go on to Sheet 10
TA140934
21-31