TM 9-2350-222-20-1-5
HYDRAULIC RESERVOIR LINE FLUID FILTER ELEMENT REPLACEMENT (Sheet 3 of 3)
INSTALLATION:
1.
Install filter element (A) into tube (B).
2.
Install preformed packing (C) onto filter
element (A).
3.
Install preformed packing (D) into filter housing
(E).
4.
Install two backup rings (F) onto filter element
(A).
By hand, install tube (B) with filter element (A)
5.
into filter housing (E) making sure packings are
seated.
6.
Using 1-1/2 inch wrench on nut on tube (B),
tighten tube (B).
7.
Install lockwire (Item 59, Appendix D) through
hole (G), upper end of tube (B), and through
hole (H) in filter housing (E).
Refill hydraulic reservoir with oil and check for
8.
leaks (LO 9-2350-222-12).
End of Task
TA141168
18-66