TM 9-2350-222-20-1-4
INFRARED POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT
(Sheet 4 of 5)
INSTALLATION:
1.
Position mount (A) on outside of bracket (B). Insert screw (C) through inside of bracket (B).
Install mount (A), washer (D), and nut (E) onto screw (C).
2.
Using 1/4 inch wrench to hold nut (E), use
screwdriver to tighten screw (C).
3.
Repeat steps 1 and 2 to install remaining
mounts (A) into brackets (B).
4.
Position washer (F) on screw (G). Install screw (G) through mount (A), washer (H), hole (J) in
power supply (K), washer (L), ground strap (M), washer (L), and washer (N). Using 7/16 inch
wrench to hold screw (G), use 7/16 inch socket to tighten nut (P).
5.
Using same procedure described in step 4,
except omitting washers (L) and ground strap
(M), install power supply (K) onto brackets (B).
Go on to Sheet 5
TA139760
10-205