TM 9-2350-222-20-1-3
AIR CLEANER (ARMORED) CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 1)
TOOLS: Cross-tip screwdriver
SUPPLIES: Lockwasher (MS35338-41) (4 required)
REFERENCE: TM 9-2350222-10
PRELIMINARY PROCEDURE:
steps 1 thru 4)
NOTE
All air cleaner circuit breakers are removed and installed the
same.
REMOVAL:
1.
Using screwdriver, remove screws (A) and lockwashers (B) securing circuit breaker (C) to cover (D).
Throw lockwashers away.
2.
Remove circuit breaker (C).
3.
Disconnect two electrical leads (circuit 415).
INSTALLATION:
1.
Position circuit breaker (C) onto cover (D).
2.
secure circuit breaker (C) to cover (D). Using
screwdriver, tighten screws (A).
3. Connect two electrical leads (circuit 415).
thru 7).
5.
Check operation of blowers (TM9-2350-222-10)
End of Task
TA141395
7-133