TM 9-2350-222-20-1-3
AIR CLEANER FILTER ELEMENT CLEANING OR REPLACEMENT (TOP LOADING)
(Sheet 5 of 5)
Make sure that filter element (B) is prop-
40
erly positioned so that door arms (D) en-
gage locking pins on sides of filter element.
WARNING
To prevent screws from pulling out of
box and injuring personnel, a minimum of
200 pounds must be placed atop the
door before installing screws.
Close door (A) and, using socket, install
5*
screws (E).
6.
Using socket, tighten screws (E) to secure
door (A).
Press indicator reset button (F) to make
7.
sure indicator shows clear window.
End of Task
TA249077
Change 2
7-114