TM 9-2350-222-20-1-3
AIR CLEANER (ARMORED) BLOWER FAN GROUND LEAD REPLACEMENT
(Sheet 1 of 2)
7/16 in. socket with 1/2 in. drive
TOOLS:
10 inch extension with 1/2 in. drive.
SUPPLIES: Lockwashers (MS35335-33) (2 required)
REFERENCE: TM 9-2350-222-10).
PRELIMINARY PROCEDURE: Remove air cleaner cover and gasket (page 7-148,
steps 1 thru 4).
WARNING
If NBC exposure is suspected, all air filter
media should be handled by personnel
wearing protective equipment. Consult
your NBC Officer or NBC NCO for appro-
priate handling or disposal instructions.
REMOVAL:
1.
Disconnect two connectors (A) from blower
leads (B).
2. Using socket, remove screw (C) and two
Go on to Sheet 2
7-138 Change 3