TM
5-5420-226-20-1
DETAILED
TROUBLESHOOTING
PROCEDURE
Symptom-40
INDICATOR
- GAGE
T
(Continued)
Check
basket-indicator
panel
harness
(CKT 27) for
continuity
from connector
at instrument
panel to
connector
at master
control
panel.
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
OFF.
l Displace
master
control
panel
(page
10-33).
l Disconnect
basket-control
panel
accessories
harness
connector
from
master
control
panel.
l Set multimeter
to OHMS
X 1 sc~le and zero
meter, or
use STE/lCE
Test
No. 91 (page
4-83).
l Check that red probe of meter is still connected
to
contact
H (CKT
27) of basket-indicator
panel harness
connector
at instrument
panel
(Step
1
).
l Connect black probe to contact H (CKT 27) of basket-
control
panel
accessories
harness
connector.
I
TO CONTACT
H
(CKT 27) OF BASKET-
[ illNDICATOR
PANEL
HARNESS
CONNECTOR
AT
INSTRUMENT
PANEL
(STEP
1
)
OONTACT
H
\olD lEco~~ F*:*%::.
MASTER
CONTROL
PANEL
(REAR
VIEW)
TA107179
4-490