TM
5-5420-226-20-1
Symptom-39
DETAILED
TROUBLESHOOTING
PROCEDURE
T
INDICATOR
- GAGE
(Continued)
)Checkfrontaccessory
harness
(CKT 30 or CKT 31)
for continuity
from connector
at bulkhead
disconnect
to basket
disconnect.
First
Technician
(Operators
Station)
l Install gage instrument
paneI (page
10-112)
Second
Technician
(Commanders
Station)
l
l
l
Displace
front accessory
harness
connector
at bulkhead
disconnect
(page
10-269).
Connect
red probe of meter
to contact
of faulty circuit
(M for CKT
30: N for CKT
31) in front
accessory
harness
connector
at bulkhead
electrical
disconnect.
Connect
black probe of meter to contact
of faulty circuit
(E for CKT
30; F for CKT
3 I) in front
accessory
harness
connector
at basket
disconnect.
m
M (CKT 30)
~
N (ckT
31)
A
()~o-0- 0DISCONNECTS--
OL q
*
,- ---
co
OM @
BASKET
DISCONNECTS
TA107176