TM 5-5420-226-20-1
Symptom-17
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STOPPING
(Continued)
First
Technician
(Commanders
Station)
I
l Check if meter indicates
continuity.
Does meter
indicate
continuity?
)
l Inspect
basket-control
panel
starting
harness
for bent/
broken
connector
contacts
or loose
CKT 544 wire at
rear of connectors.
l Repair connectors
if
defective
(page
10-298).
l If connectors
are not
defective,
notify
support
maintenance
of a defective
basket-control
panel starting
harness.
l Install basket-control
panel
starting
harness
connector
at basket
disconnect
(page
10-270).
l Connect
basket-control
panel
starting
harness
connector
to master
control
panel.
l Install master
control
panel
(page
10-33).
CKT
f
t
CONTACT
TA107003
4-314