TM 5-5420-226-20-1
DETAILED
TROUBLESHOOTING
PROCEDURE
Symptom-17
VEHICLE
OPERATION
- POWERPLANT,
STOPPING
(Continued)
ICheck
fuel shut off harness
(CKT 54) for continuity
from ENGINE FUEL SHUT OFF switch to fuel shut off
circuit
breaker.
Second
Technician
(Operators
Station)
l
o
l
l
Set MASTER
BATTERY
switch
OFF.
Set multimeter
to OHMS
X 1 scale and
zero
meter,
or use STE/ICE
Test
No.
91 (page
4-83).
Connect
red probe
of meter
to fuel shut
off harness
connector
(CKT
54) at circuit
breaker.
Connect
black
probe
of meter
to fuel shut
off harness
connector
(CKT
54) at switch.
l Check if meter indicates
continuity.
Does meter
indicate
continuity?
Replace
master
control
panel
starting
harness
(page
10-97).
Reconnect
fuel shutoff
harness
(CKT 54) to circuit
breaker
and to ENGiNE
FUEL
SHUT OFF switch.
Reconnect
master
controi
panel power
harness
(CKT
54) to circuit
breaker.
4-318
-J
Yl-fl-
FUEL SHUT OFF
CIRCUIT
BREAKER
e
l
l
Repiace master control panel
fuei shut off harness
(page 10-109).
Reconnect master control
panel power harness (CKT
54) to circuit breaker.
Reconnect CKT 54A
connector to ENGiNE FUEL
SHUT OFF switch.
TA107007