TM 5-5420-226-20-1
Symptom-9
DETAILED
TROUBLESHOOTING
PROCEDURE
T
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
.
Check basket-control
panel starting harness (CKT
486) from master control panel to primer pump for
continuity.
First
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
OFF.
l Displace
master
control
panel
(page
10-33).
l Disconnect
basket-control
panel
starting
harness
connector
from
master
control
panel.
o
Set mulitmeter
to OHMS
Xl
scale and
zero
meter,
or use STE/ICE
Test
No.
91 (page
4-83).
l Connect
red probe
of meter
to contact
G (CKT
486)
of basket-control
panel
starting
harness
connector
at
master
control
panel.
l Connect
black
probe
of meter
to first one (CKT
486) lead at primer
pump
and
then
to other
lead.
l Check if meter indicates
continuity
at one of leads
(CKT
486) at primer
pump.
/
Did multimeter indicate continuity at one of the
two (CKT 486) leads at the primer pump?
n
(
m.
CONTACT
-Ww.
hMASTERCONTROL
(REAR
VIEW)
n.
1
PANEL
)
l Inspect basket-control
panel
starting harness for
bent/broken
connector
contacts or loose (CKT 486)
wire at rear of connectors.
l Repair connectors if
defective
(page 10-298).
l If connectors are not
defective,
notify support
maintenance of a defective
basket-control
panel starting
harness.
l Connect basket-control
panel
starting harness connectors
to primer pump and master
control panel.
l Install master control panel
(page 10-33).
TA106913
4-224