TM 5-5420-226-20-1
Symptom-9
DETAILED
TROUBLESHOOTING
PROCEDURE
._CY
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
--
Caution-_
...=
I
Do not press STARTER button for
I
I
more than 14 seconds.
I
Lr-.
-0..0-
----
J
)
m
Check basket-control
panel starting harness (CKT
486) at manifold preheat switch connector for
electrical power.
~irst Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
OFF.
l Place manual
fuel shutoff
handle
in OFF
(out)
position.
l Disconnect
both
harness
connectors
(CKT
486)
from
preheat
switch
at primer
pump.
l Set multimeter
to measure
18 to 30 volts dc, or use
STE/ICE
Test
No.
89 (page 4-81).
l Connect
red probe
of meter
to one of the connectors
(CKT
486) at manifold
preheat
switch
and black
probe
to ground.
l Set MASTER
BATTERY
switch
ON.
l Press STARTER
button
for about
10 seconds,
then
release.
l Check if meter indicates
10 to 30 volts dc.
l Repeat above check moving red probe of meter to
other
connector
(CKT
486) at manifold
preheat
switch.
l Place manual
fuel shutoff
handle
in ON
(down)
position.
Did meter indicate 18 to 30 volts dc at one of the
connectors?
n
+HF
TO VEHICLE
GROUND
\w3)
r.CKT 486
w/
il Check manifold preheat
switch for continuity.
I
YES
~
l See Step
12
.
TA106912