TM 5-5420-226-20-1
Symptom-8
DETAILED
TROUBLESHOOTING
PROCEDURE
.T
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
)
m
Check high voltage ignition lead for short to ground.
First
Technician
(Powerphmt)
l Connect engine electrical harness connector
to manifold
heater
ignition
unit
at cold manifold
heater.
l Disconnect
high
voltage
ignition
lead from
manifold
heater
ignition
unit at cold manifold
heater
(keep
this
lead).
l Disconnect
high
voltage
ignition
lead from
manifold
heater ignition
unit and spark plug at manifold
heater on
opposite
side of engine
and connect
it to ignition
unit
and spark
plug of cold
manifold
heater.
Second
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
ON.
l Press STARTER
and
preheat
switches
at the same
time,
hold
on for approximately
10 seconds,
then
release.
First
Technician
(Powerplant)
l Check if heat can be felt from manifold
heater.
)
Did manifoid heater get hot?
I
r
HIGH
IGNITION
VOLTAGE
UNIT
LEAD
(RIGHT
SIDE OF ENGINE
SHOWN)
l Replace manifoid heater
Replace high voitage ignition
ignition unit (page 7-289).
iead (page 7-289).
l instaii high voitage ignition
iead to manifoid heater
without a iead.
TA1069O9
4-220