TM 5-5420-226-20-1
(
Symptom-1
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STARTING
T
(Continued)
)
I
Check
master
control
panel accessories
harness
from intermediate
connector
to panel connector
for continuity.
First
l
l
l
l
Technician
(Operators
Station)
Disconnect
master
control
panel
accessories
harness
intermediate
connector
(CKT
14) from
master
control
panel
power
harness.
Connect
red probe
of meter
to contact
J (CKT
14)
of accessories
harness
panel
connector.
Connect
black
probe
of meter
to intermediate
connector
(CKT
14).
Check
if meter
indicates
continuity.
Does meter
indicate
continuity?
)
l Replace
master
control
panel
power
harness
(page
10-38).
l Connect
basket-control
panel
accessories
harness
to
master
control
panel.
Lo-
t
+
0
\
14
CKT
10-14
IReplacemastercontrolpanel
accessories
harness
I
m+
(page
10-38).
\
J
TA1068O2