TM 5-5420-226-20-1
Symptom-1
DETAILED
TROUBLESHOOTING
PROCEDURE
VEHICLE
OPERATION
- POWERPLANT,
STARTING
(Continued)
3
Check
STARTER
switch
for continuity.
First
Technician
(Operators
Station)
l Set MASTER
BATTERY
switch
OFF.
#
l Disconnect
master
control
panel
power
harness
connector
(CKT
14) from
STARTER
switch,
l Set multimeter
to OHMS
Xl
scale and
zero
meter
or use STE/ICE
Test
No.
91 (page
4-83).
l Connect
red probe
of meter
to one contact
and
black
probe
to other
contact
of starter
switch,
l Press and release STARTER
switch.
l Check if meter indicates
continuity
while
STARTER
switch
is pressed.
Does meter
indicate
continuity.?
I
STARTER
SWITCH
)
l Replace
starter
switch
(page
10-38).
l Connect
basket-control
panel
accessories
harness
connector
to master
control
panel.
TA1068O1
-.
4-112