Using EDS Program

OPERATOR AND FIELD MAINTENANCE EDS SOFTWARE INSTALLATION ON THE MSD-V2 FOR RECOVERY VEHICLE, FULL-TRACKED: HEAVY M88A2
Page Navigation
  1    2  3

img
.
NOTE
Any one of the following messages will be returned:
System has successfully passed self test.
System has failed self test.
Test Details and Observations (any of the following may appear)
The PC cannot communicate with 1553 card.
Cannot communicate with R/T.
All signals connected through cable assembly 2W505 are below range or open.
All signals at R/T jack J1 are below range or open.
All signals at R/T jack J2 are below range or open.
All signals at R/T jack J3 are below range or open.
All signals at R/T jack J5 are below range or open.
4. Refer to IETM Field Troubleshooting Procedures, FIELD TROUBLESHOOTING INDEX,
TEST EQUIPMENT to troubleshoot the EDS.