TM 9-2350-222-34-1
SHIFTING CONTROL CONNECTING LINK REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
1. Position link (A) in vise. Using wrench, install nuts (B and C) onto link (A).
2. Using wrench, install rod end (D and E) onto link (A).
3. Position link assembly (A) into brackets (F and G) and using socket install screws (H and J) through brackets (F and
G) and rod ends (D and E).
4. Perform linkage adjustment (TM 9-2350-222-20-1).
5. Install right ammunition rack (TM 9-2350-222-20-1).
End of Task
TA130676