TM 9-2350-222-20-2-3-2
LAST ROUND STOP SWITCH INSTALLATION PROCEDURE
36-91.
TOOLS: Crosstip screwdriver (Phillips)
11/32" open end wrench
Tape measure
PERSONNEL: Two
REFERENCES: JPG for procedure to connect electrical connectors
EQUIPMENT LOCATION INFORMATION:
CALLOUT
FOLDOUT
EQUIPMENT
Driver's Master Control Panel
20
Flexible Chute
EQUIPMENT CONDITION: Driver's master control panel MASTER BATTERY switch set to OFF
FRAME 3
Procedure
Step
Open ammunition box door (1).
1.
Using screwdriver, put in two screws (2) holding bracket (3) to last round stop switch
2.
(4).
Soldier A: Hold shims (5) bracket (3) and switch (4) in place against outside of
3.
ammunition box.
Soldier B: Using screwdriver and wrench, attach button guard (6), shims (5), bracket (3)
nuts (9).
4.
Using tape measure, measure distance between ramp button (10) and inside edge of
ammunition box. Distance should be between 5-3/8" and 5-5/8".
NOTE
If distance obtained in step (4) is not between 5-3/8"
and 5-5/8", remove or install shims (3) as required to
obtain necessary distance.
Connect two cables (11) to cable connectors 1W13P4 and 1W13P5 (JPG).
5.
Using screwdriver, install wiring harness clamp (12).
6.
7.
Close ammunition box door (1).
END OF TASK
Para 36-91
36-198