TM 9-2350-222-20-2-3-2
36-22.
CUPOLA POWER SWITCH INSTALLATION PROCEDURE
TOOLS:
Flat-tip screwdriver
PERSONNEL One
REFERENCES:
JPG for procedure to connect electrical connectors
EQUIPMENT LOCATION INFORMATION:
EQUIPMENT
FOLDOUT
CALLOUT
Driver's Master Control Panel
11
Cupola Electrical Power Control Panel FO-2
2
Driver's master control panel MASTER BATTERY switch set to OFF.
EQUIPMENT CONDITION:
NOTE
Except for location, the installation procedures for the
cupola power switch are the same for the early or late
models.
Para 36-22
36-56 Change 1